Nous utilisons des cookies pour améliorer votre expérience en ligne. En poursuivant votre navigation sur ce site, nous supposons que vous acceptez notre utilisation des cookies.
catégories

La haute fréquence 32KW 50KW 65KW a fixé la machine de rayon X avec le système numérique YSDR-500B1

No. d'article: YSX500G
Système de rayons X fixe haute fréquence 32KW 50KW 65KW 50KW 630mA machine à rayons X numérique fixe à rayons X
Description

High Frequency 50KW Fixed X Ray Machine YSX500G For sale
YSX500GYSX500GYSX500G
Features
 
1.  High precision control mode: Adopting HF (≥30kHz) inverter circuit combined with a nalog & digital double-loop control mode
(composed of microprocessor and PWM dedicated chip).
 
 
2. High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality images are easily achieved and radiation to patients is minimized.
 
 
3. High-precision tube current control: The heating of x-ray tube adopts dual-stage high frequency converter, through taking sample tube current by high-speed running A/D converter and implement real-time control through micro-processor.
 
4. Various parameter  setting keys: You can select kV, mA and mAs to set the desirable radiography conditions. With quick human body parts programming, it simplifies the operation procedures.

 
5. Self-protection & self-diagnosis: Once malfunction occurs, generator will self-protection and give an alarm.
 
 
6.  Compact structure, reduce installation space.
 
 
7. Digital upgradable.
 
YSX500G & YSX0200G Technical index of main component
CONTENTS YSX200G YSX500G
Intermittent mode 100kV ,200mA,20kW 100kV ,500mA,50kW
Power Voltage 380V±10% 50Hz±10%
tube current Radiography   16mA~200mA Radiography32mA~630mA
Output Voltage Radiography 40-125KV  step 1kV;
resistance power less than  0.5Ω
Output power 20kW 50kw
Exposure Time Radiography 0.0025s~6.4s adjustable Radiography  3ms~6s   adjustable
Nominal Frequency 30kHz
Speed of anode rotating 2800r/min
Anode heat capacity 140KHU 150KHU
Focus Small focus:1.0mm  Big focus:2.0mm
Length*width*height of bed surface 2000mm×750mm×690mmDeviation:±10mm
Horizontal movement distance of table ≥200mm
Vertical movement distance of table ≥900mm
Distance from table surface to film 50mm±2mm
Distance of vertical movement 770mm±10mm; 800mm-1100mm

Product  Configuration
No Part Name Qty
1 X-ray tube 1
2 Radiographic Table 1
3 collimator 1
4 Microcomputer console 1
5 High-voltage generator, 1
6 High voltage cable 2
7 Vertical bucky stand( Optional) 1


obtenir le prix
Écrivez votre demande ci-dessous et nous vous contacterons dans les 24 heures!

Commentaires

1/3
X